Technical Knowledge about Transformer Testing and Transformer Testing Bench

  

Test Rating

Current at 1100V

Current at 2200V

Current at 3300V

KVA Rating of

Booster Transformer

630KVA

33.06A

16.53A

11.02A

63KVA

1000KVA

52.50A

26.25A

17.50A

100KVA

1600KVA

83.98A

42.99A

27.99A

160KVA

2500KVA

131.25A

65.62A

43.75A

250KVA

5MVA

262.50A

131.25A

87.50A

500KVA

10MVA

525A

262.50A

175A

1000KVA

 Transformer Test Bench for SC/OC Test, HV Test, and DVDF Test 

We are manufacture of Transformer Test Bench for above tests for any range of transformer up to 10MVA i.e. for Distribution and Power transformer.

These test benches are well designed and available with all the technical information and most economical. We are always ready to reply technical query of customer and will provide after sale service.

Design Consideration

Take an example of test bench for 5MVA transformer. Its full load current is about 262.5A at 11KV, 131.25A at 22KV and 87.5A at 33KV rating.

So we will require Booster Transformer which can supply above current. Taking maximum % impedance 7% it will require Booster of rating 770V P-P for 11KV or 1520V P-P for 22KV and 2290 for 33KV.

Power Factor of transformer under test is is the range of 0.06, so at full load power drawn is √3×770×262×0.06 = 21KW

We cannot afford to draw 262A from the source at it is unnecessary and will create problems for stability and dropping of voltage.

For full load current to meet this requirement, test bench should not draw more than following i.e. at power factor of 0.8

√3×415×I×0.8 = 21KW

I=21000/575 =36A

Hence we have to introduce capacitors first after variac for full load current test. Required rating is 50A but at the most we can have variac of 100A rating taking all the categories into account and remaining current i.e.  262A-40A=222A can be supplied by capacitor bank introduced in between.

Similarly we can reduce requirement of variac current for HV test and DVDF test.

System is fully build up with the contactors and provide inter-locking and protection such as:

1)                   When one type of test OC/SC or HV or DVDF is being carried out for other test will be cut automatically and will be indicate on panel.

2)                   For operation of motor generator set will be tripped when current exceed from the prescribe limit.

3)                   For HV testing customer can test current limit on the panel and circuit will be tripped when current exceed.

4)                   Emergency switch is provided for emergency stopping supply. Moreover incoming  MCCB will take case of tripping. 

         For further information contact us. 

 

 


Search

Contact us

UMA Electronics Enterprise

HEAD OFFICE ADDRESS 

A 404 ,Vaishali Nagar
Jaipur, Rajasthan
INDIA, Pin: 302021

Phone: 0141-2240935

SALES OFFICE ADDRESS

H-1/54
RIICO Industrial Area
Bindayaka,
Jaipur, Rajasthan
India, Pin: 302012

Phone: 0141-2240935, 09928585256/ 08107587107


Factory Address

H-1/54
RIICO Industrial Area
Bindayaka,
Jaipur, Rajasthan
India, Pin: 302012

Trustware technologies

H-1/54
RIICO Industrial Area
Bindayaka,
Jaipur, Rajasthan
India, Pin: 302012

ph.no.6350540480,8209438361


Sitemap

© 2021 UMA ELECTRONICS

Website Designing and Website Development by eBRANA WebTechnologies Jaipur Private Limited

to top ↑